When temperatures drop below freezing, one of the most common reasons a boiler stops working is a frozen condensate pipe. The good news is that it is often simple to fix yourself. This guide explains how to spot it, how to thaw it safely and how to stop it happening again.

What is a condensate pipe?

Modern condensing boilers produce a small amount of acidic water as they run. The condensate pipe carries this water away to a drain. It is usually a white or grey plastic pipe that leaves the boiler and often runs outside the house.

Because only a little water trickles through it, the pipe can freeze quickly in a cold snap, especially where it runs outside. When it freezes, the water backs up and the boiler shuts down to protect itself.

Signs your condensate pipe has frozen

  • The boiler stops working during freezing weather
  • A fault code or warning light appears on the boiler display
  • You hear a gurgling noise from the boiler or the pipe
  • You have no heating or hot water, but the gas and power are fine

How to thaw a frozen condensate pipe

  1. Find the pipe. Follow the plastic pipe from the boiler to where it leaves the house and runs to a drain.
  2. Find the frozen section. It usually freezes at the lowest point, a bend or the open end. The pipe may feel colder there or show ice.
  3. Apply gentle heat. Pour warm water slowly over the frozen section. Boil a kettle and leave it to cool for 10 to 15 minutes first. A hot water bottle or a microwaveable heat pack held against the pipe also works.
  4. Reset the boiler. Once the pipe has thawed, follow your boiler manual to reset it. It may take a few minutes to restart.

Do not use boiling water. It can crack or split the plastic pipe. Do not climb ladders to reach a high pipe in icy weather. Call an engineer instead.

How to stop the condensate pipe freezing again

  • Insulate the outside section. Waterproof pipe lagging helps the pipe stay above freezing.
  • Use a wider pipe outside. Industry guidance, based on BS 6798, recommends that any external condensate pipe is at least 32mm in diameter. A wider pipe is much less likely to freeze solid.
  • Shorten or reroute the pipe. Where possible, running the pipe internally to a drain inside the home avoids the cold altogether.
  • Keep the heating ticking over. In very cold spells, leaving the heating on at a low setting can stop the pipe freezing overnight.

If your condensate pipe freezes every winter, it is worth having an engineer check how it was installed. Upgrading or rerouting the pipe is usually a quick job.

Frequently asked questions

Can I pour boiling water on a frozen condensate pipe?

No. Boiling water can crack the plastic. Use warm water from a kettle that has cooled for 10 to 15 minutes.

Will a frozen condensate pipe damage my boiler?

Usually not. The boiler locks out to protect itself. Once the pipe has thawed and the boiler is reset, it should work normally.

Why does my condensate pipe keep freezing?

The most common reasons are a narrow pipe, a long run outside, or no insulation. An engineer can upgrade or reroute it.

What if the boiler still will not start?

Check the other common causes in our guide to a boiler not firing up, or see what to do when your boiler breaks down in winter.